Home Solar System Accessories Eco-Worthy Battery Interconnect Cable
Skip to product information
💎Prime Day Sale

Eco-Worthy Battery Interconnect Cable

Eco-Worthy Battery Interconnect Cable

Regular price £21.99
Sale price £21.99 Regular price £23.99
Sale Sold out
Taxes included. Shipping calculated at checkout.

SKU:

SKU:UK-L0335PM8-1

·High quality copper material made, durable.

·UV and ozone resistant.

·Protected against short circuits and ground leakages.

·For use outdoors, explosive areas, industrial, commercial applications.

Read more
Style

Total price

£21.99
Buy It Now

Free Shipping

Return Guarantee

Secure Payment

or 4 interest-free payments of £5.49 with

Installments available at checkout
Shop with Confidence at Eco-Worthy

Free & Fast Delivery

14-Day Money-Back Guarantee

Up To 10-Year Warranty

Lifetime Customer Support

Pay with ease

  • American Express
  • JCB
  • Mastercard
  • PayPal
  • Venmo
  • Visa

Trusted delivery

View full details
X
£15.99 £18.99
Buy It Now
Battery Interconnect Cable

High-quality copper battery interconnect cable with UV and ozone resistance. Ideal for solar systems, lithium batteries, RVs, marine, and energy storage applications.

Technical Specifications

2AWG (35mm²) 12 Inch / M8 Rings
6AWG (16mm²) 13 Inch / M6 Rings
6AWG (16mm²) 13 Inch/ M8 Rings
10AWG (6mm²) 12 Inch / M5 Rings

Cable Type:

Battery to Battery

Normal Cross Sectional Area of the Conductor (mm2):

35

Rating Voltage:

600/1000V

Waterproof:

IP 65 Protection

Rating Current:

150A

Temperature:

-76°F to +392°F

Length:

0.30 meters(12 inch)

Connector:

Lug

Conductor:

Tinned copper wire

Weight:

0.3kg/0.66lb

AWG:

2

Cable Type:

Battery to Battery

Normal Cross Sectional Area of the Conductor (mm2):

16

Rating Voltage:

600/1000V

Waterproof:

IP 65 Protection

Rating Current:

64A

Temperature:

-76°F to +392°F

Length:

0.35 meters(13 inch)

Connector:

Lug

Conductor:

Tinned copper wire

Weight:

0.154kg

AWG:

6

Cable Type:

Battery to Battery

Normal Cross Sectional Area of the Conductor (mm2):

16

Rating Voltage:

600/1000V

Waterproof:

IP 65 Protection

Rating Current:

64A

Temperature:

-40°F to +185°F

Length:

0.35 meters(13 inch)

Connector:

Lug

Conductor:

Tinned copper wire

Weight:

0.3kg/0.66lb

AWG:

6

Cable Type:

Battery to Battery

Normal Cross Sectional Area of the Conductor (mm2):

6

Rating Voltage:

450/750V

Waterproof:

IP 65 Protection

Rating Current:

30A

Temperature:

-76°F to +392°F

Length:

0.30 meters(12 inch)

Connector:

Lug

Conductor:

Tinned copper wire

Weight:

0.046kg

AWG:

10

Included in the Box
  1. 2AWG (35mm²) 12 Inch / M8 Rings
  1. 6AWG (16mm²) 13 Inch / M6 Rings
  1. 6AWG (16mm²) 13 Inch / M8 Rings
  1. 10AWG (6mm²) 12 Inch / M5 Rings

Frequently Asked Questions

How do you test lithium battery performance?

+
When measuring the battery's rated voltage, it is recommended to first disconnect the connection wires between the battery and the load, inverter, and charger to ensure accurate results.

What’s the relationship between lithium battery voltage and SOC?

+
①During battery use, it is recommended to keep the SOC at 20%~80% to extend the battery life (charge to at least 13.3V) ②If the battery is not used for a long time (more than half a year), at least 50% of the power should be guaranteed, otherwise the battery may be over-discharged and damaged. ③After fully charged, if the battery voltage is greater than or equal to 13.3V after one hour without any connections, it is within the normal range. ④This table is only the test result under ideal conditions. After adjusting to the correct parameters, the voltage drops to 13.26V, which does not prove that the battery capacity is insufficient. The actual capacity needs to test the power of the connected load and the length of use.

How to activate a protected lithium battery?

+
A:Take 12.8V battery as an example, when the voltage drops to 0~2V, the battery BMS may enter protection state, and the battery needs to be reactivated. Method 1: Use an AC-DC LiFePO4 Lithium charger with activation function, set the charging voltage to 14.6V for charging. After 30~60 minutes, use a multimeter to measure the voltage. If the voltage changes, continue to charge. Method 2: Use a solar panel and controller with activation function. In an environment with good lighting conditions, connect the solar panel, controller, and battery, and set the charging voltage to 14.6V for charging. After 30~60 minutes, remove the battery connection wire, use a multimeter to measure the voltage. If the voltage changes, continue to charge.

Solar Panel Performance Testing Method

+
Disconnect all wires from the solar panel. Use a multimeter to measure both short-circuit current (Isc) and open-circuit voltage (Voc) under sunny outdoor conditions.Note: Performance may vary due to controller temperature and battery charge level.

What kind of warranty and support do you offer?

+
We provide up to a 10-year warranty on key battery models, along with U.S.-based support. Our team assists with installation guidance, troubleshooting, and system planning to ensure a smooth experience.