Eco-Worthy 120W 240W 12V expandable Solar Kit is an ideal choice. This system could generate approximately 0.48kWh 0.96kWh per day. It can be used for several different purposes, including cottages, weekends, cabins, boats, RVs, Campers, etc. Whatever the kit is used for, you can rest assured that you are purchasing a quality system. Run a small stereo, laptop computer, cell phone charger, lights or TV.

120W 240W 12V (1/2x120W) Complete Off Grid Solar Kit
Technical Specifications
LiFePO4 12V 100Ah Lithium Battery
12V 50Ah LiFePO4 Lithium Battery XT60
Bifacial 120W 12V Monocrystalline Solar Panel
600W Off Grid Pure Sine Wave Inverter
30A PWM LCD Display Solar Charge Controller
Z Style Solar Panel Mounting Brackets
Solar Extension Cables Wires with MC4
Y Parallel Branch Connectors MFF
Battery Capacity:
100Ah
Battery Power:
1280Wh
Battery Voltage:
12.8V
Maximum Charge/ Discharge Current:
100A/100A
Charge Temperature Range:
0-45℃
Discharge Temperature Range:
﹣20-55℃
Maximum Charge Voltage:
14.6V
Discharge Cut-Off Voltage:
10V
Screw size:
M8
Battery Size:
260*168*214mm(10.2*6.6*8.4inch)
Battery Weight:
10.5 kg
Battery Capacity:
50Ah
Battery Power:
640Wh
Battery Voltage:
12.8V
Maximum Charge/ Discharge Current:
50A/50A
Charge Temperature Range:
0-55℃
Disharge Temperature Range:
﹣20-55℃
Maximum Charge Voltage:
14.6V
Discharge Cut-Off Voltage:
10V
Screw size:
M6
Battery Size:
232*135*181mm(9.1*5.3*7.1inch)
Battery Weight:
5.74kg(12.65lbs)
Rated Power:
120W
Solar Cell:
Monocrystalline
Maximum/Peak Voltage(Vmp):
20.2V
Open Circuit Voltage(Voc):
24.5V
Short circuit current:
5.94A
Maximum current:
6.24A
Output Tolerance:
-(0.38+/-0.01)%/℃
Temperate coefficient of Isc:
-40℃~ +85℃
Temperate coefficient of Voc:
Aluminum alloy frame
Temperature range:
15.43 lbs(7.0 kg)
Frame:
37.8x26.3x1.4in (960*670*35mm)
Weight:
Size:
Battery Input Voltage:
12V
Rated Power:
600W
Peak Power:
1200W
Output Waveform:
Pure Sine Wave
Output Voltage:
230Vac
USB Output:
5V 1.2A
Extension Cable:
6mm²,9AWG,1 meter
Output Frequency:
50HZ ± 0.3HZ
AC Output Sockets:
1
Temperature:
-20℃-40℃
Battery voltage:
12V/24V
Charging mode:
PWM
Max Charge current:
30A
Discharge current:
30A
Max.PV Open-Circuit Voltage:
<50V
USB Output:
5V/2A
Working Temperature:
-20℃~60℃
Weight:
150g
Size:
138*85*30mm
Material:
Aluminum Alloy
Size of Screw and Nut:
M6
Weight:
0.85kg
Cable Type:
Connecting Solar Panels to Charge Controllers
Rating Voltage:
600/1000V
Length:
5 meters(16 ft)
Conductor:
Tinned copper wire
AWG:
12
Normal Cross Sectional Area of the Conductor (mm2):
4
Waterproof:
IP 65 Protection
Temperature:
40°F to +185°F
Connector:
MC4
Model:
12AWG
Rated Current:
30A
Test Voltage:
6000V
Included in the Box
User manual
Eco-Worthy Bluetooth APP - User Manual
DownloadEco-Worthy 12V 100Ah LiFePO4 Lithium Battery with Bluetooth - User Manual
DownloadEco-Worthy 12V 50Ah LiFePO4 Lithium Battery - User Manual
DownloadEco-Worthy Bifacial 120W 12V Monocrystalline Solar Panel - User Manual
DownloadEco-Worthy 600W Off Grid Pure Sine Wave Inverter 12V to 230V- User Manual
DownloadEco-Worthy 12V/24V 30A PWM Solar Charge Controller - User Manual
DownloadFrequently Asked Questions
How do you test lithium battery performance?
+
When measuring the battery's rated voltage, it is recommended to first disconnect the connection wires between the battery and the load, inverter, and charger to ensure accurate results.
What’s the relationship between lithium battery voltage and SOC?
+
①During battery use, it is recommended to keep the SOC at 20%~80% to extend the battery life (charge to at least 13.3V) ②If the battery is not used for a long time (more than half a year), at least 50% of the power should be guaranteed, otherwise the battery may be over-discharged and damaged. ③After fully charged, if the battery voltage is greater than or equal to 13.3V after one hour without any connections, it is within the normal range. ④This table is only the test result under ideal conditions. After adjusting to the correct parameters, the voltage drops to 13.26V, which does not prove that the battery capacity is insufficient. The actual capacity needs to test the power of the connected load and the length of use.
How to activate a protected lithium battery?
+
A:Take 12.8V battery as an example, when the voltage drops to 0~2V, the battery BMS may enter protection state, and the battery needs to be reactivated. Method 1: Use an AC-DC LiFePO4 Lithium charger with activation function, set the charging voltage to 14.6V for charging. After 30~60 minutes, use a multimeter to measure the voltage. If the voltage changes, continue to charge. Method 2: Use a solar panel and controller with activation function. In an environment with good lighting conditions, connect the solar panel, controller, and battery, and set the charging voltage to 14.6V for charging. After 30~60 minutes, remove the battery connection wire, use a multimeter to measure the voltage. If the voltage changes, continue to charge.
Solar Panel Performance Testing Method
+
Disconnect all wires from the solar panel. Use a multimeter to measure both short-circuit current (Isc) and open-circuit voltage (Voc) under sunny outdoor conditions.Note: Performance may vary due to controller temperature and battery charge level.
What kind of warranty and support do you offer?
+
We provide up to a 10-year warranty on key battery models, along with U.S.-based support. Our team assists with installation guidance, troubleshooting, and system planning to ensure a smooth experience.